Телефон: +7 921 936 2039


Области применения: введение



















Неинвазивный клинический анализ крови

A new non-invasive spectroscopic method has been developed, based on absolute hemoglobin, cytochrome and water concentration measurements in tissue. The method was implemented in the newly designed HemoSpec-2000.

The HemoSpec is based on a 2048-pixel single channel fiberoptic spectrometer, a tungsten light source and a reflection probe with holder. The system is integrated in a 19” industrial mobile equipment carrier with a PC-based industrial workstation and touch-screen TFT-LCD display.

Optionally the HemoSpec can be configured with a double beam 2048-pixel fiber-optic spectrometer, a combined deuterium- tungsten light source and a special reflection-probe.


Applications

The HemoSpec can be used for following applications in which continuous measurement of oxygen saturation, concentration of total, oxygenated and deoxygenated hemoglobin needs to be done. Optionally available are concentration measurements of total and reduced cytochrome aa3. Also water measurements and the concentration of NADH can be obtained. The data are registered and displayed in continuous mode on-line.

The HemoSpec has been implemented successfully in the following fields:



  • Angiology / Pharmacology - Monitoring of the oxygen saturation after the application of vaso-active substances. Oxygen changes caused by Reynaud syndrome and microcirculation diseases in tissue.


  • Dermatology - Detection of local -regional perfusion diseases, recurrence of melanomas.


  • Diabetology - Micro-angiopathy, early detection of Endotheld dysfunction and ulzeration.


  • Cardio surgery - Oxygen consumption of the heart muscle during/after bypass operations.


  • Neurosurgery / Oncology - Quantifying of oxygen  consumption of (brain) tumors before/after  radiation or operations.


  • Pediatry / Gynecology - monitoring of oxygen concentration of critically ill newborn during birth.


  • Plastic surgery / Transplantation medicine - Monitoring of transplanted and reimplanted tissues, bones or organs


  • Accident surgery - Determination of surface of burned or frozen skin.


On request we can send you copies of one of the following articles:

1. Rehrborn, H.-J., Steinberg, F., Jungmann, H., Schietzel, M., Streffer, C. (1995):

Noninvasively NIR-Reflectance-Spectroscopy of Cytochromes in Organs and Tumors. Radiation Research (1985 -1995), Congress Proceedings; Vol. 1 :Congress Abstracts, 187; Wьrzburg

2. Steinberg, F., Jungmann, H., Rцhrborn, H.-J., Schietzel, M., Streffer, C. (1995):

Noninvasive Oxygen Measurement In Tumors With A New Wide Range Scanner On NIR Reflection Spectroscopy Radiation Research (1985 -1995), Congress Proc.; Vol. 1; Congress Abstracts, 188; Wьrzburg

3. Steinberg, F., Rцhrborn, H.-J., Otto, T., Lubold K., Peschke, B. Streffer, Ch., (1996):

NIR reflection measurements of hemoglobin and cytochrome aa3 - correlation to oxygen consumption and energy metabolism - preclinical and clinical data, ISOTT, 19th - 23rd August 1996, Dundee, Scotland

4. Steinberg, F., Rцhrborn, H.-J., Scheufler, K.M., Asgari, S., Trost, H.A., Seifert, V. Stolke, D., Streffer, (1996):

NIR reflection spectroscopy based oxygen measurements and therapy monitoring in brain tissue and intracranial neoplasm - correlation’s to MRI and angiographic data. ISOTT, 19th - 23rd August 1996, Dundee, Scotland

5. Steinberg, F., Rцhrborn, H.-J., Otto, T., Scheufler. K.M and Streffer, Ch., (1997):

NIR reflection measurements of hemoglobin and cytochrome aa3 - Correlation to oxygen consumption and energy metabolism - preclinical and clinical data. Oxygen Transport to Tissue XIX, 69-77, New York 1997

6. Steinberg, F., Rцhrborn, H.-J., Scheufler, K.M., Asgari, S., Trost, H.A., Seifert, V. Stolke, D.,Streffer, (1996):

NIR reflection spectroscopy based oxygen measurements and therapy monitoring in brain tissue and intracranial neoplasm - Correlation’s to MRI and angiographic data. Oxygen Transport to Tissue XIX, 553 - 560, New York 1997

7. Asgari, S., Rцhrborn, H.J., Schдfer, H. and Stolke,D. (1999)

In Vivo Measurement of Cytochrome as a Intracellular Oxygen Parameter and Temporary focal Ischemia in Rabbit Brain Zentralbl. Neurochir.Suppl. 1999; 83

8. Asgari, S., Dцrfler, A., Rцhrborn, H.-J., Forsting, M. and Stolke,D. (2000)

In Vivo Measurement of Cytochrome as Intracellular Oxygen Parameter and Temporary Focal Cerebral Ischemia in the Rat, Journal of Cerebral Bloodflow and Metabolism (to be printed)

Rambler's Top100
© 2000-2024 ООО "ЛОКАМЕД" E-mail: avantes@rambler.ru, телефон: +7 921 936 2039, факс: +7 812 499 1500
Last Updated: 24.02.2024

спектрометр спектрометр